Genotyping

Panels

Fluidigm - Advanta™ Sample ID Genotyping Panel
Ensure that you have the right sample and sample quality
The Advanta Sample ID Genotyping Panel is a 96-SNP genotyping assay that enables sample identification and quality assessment. Using Fluidigms microfluidic technology on Biomark HD or Juno, the Advanta Sample ID Genotyping Panel workflow offers sample identification and quality assesment with decreased hands-on time and significant cost savings compared to traditional qPCR methods.
- 30 min hands-on, 4 hour total time to answer
- Quality, Gender, Ethnicity, Polymorphic and Highly expressed SNPs
- Compatible with commercially available panels like Sure Select Human all Exon, Omni Express, etc.


Preamp and Reverse Transcription Master Mixes

Fluidigm - Master Mixes
Preamp and Reverse Transcription Master Mixes
Fluidigm delivers optimized Preamp and Reverse Transcription Master Mixes for the Biomark and Biomark HD platforms. Preamplification allows for multiplex amplification of up to 96 targets. A pool of primers is prepared from the same gene expression assays to be used for qPCR. By using the real-time qPCR assays in the preamplification reaction, only the targets of interest are amplified. A limited number of cycles is used and the cDNA is amplified without significant bias.
- Optimized for small volumes
- Optimized for TaqMan Gene Expression Assays


Reagents

Agilent - Brilliant III qPCR and Brilliant HRM Master Mixes
Brilliant SNPtyping with Agilent Master Mixes
Brilliant III ultrafast probe Master Mixes provide specificity by utilizing a novel faster-activating hot start method. The hot start method minimizes the formation of primer-dimers and other off-target reactions. These reagents are robust and reproducible across fast cycling real-time platforms.
Brilliant III QPCR Ultra-Fast Probe Master Mix
- Extremely fast runs while maintaining sensitivity and great resistance to qPCR inhibitors
- Optimized protocols for most qPCR instruments
Brilliant HRM Ultra-Fast Loci Master Mix
- Platform-independent mix for high-resolution melt (HRM) analysis
-
Mutant Fast-Start Taq polymerase, optimized MgCl2 and dNTPs concentrations
- EvaGreen, release-on-demand dye for fast results for the most difficult genotypes


Integrated Fluidic Circuits (IFCs)

Fluidigm - Biomark HD IFCs
Make up to 9.216 datapoints in one run
Enhance your productivity with high-performance solutions for robust processing of samples in nanoscale reactions, enabling quick and reliable SNP genotyping. Fluidigm's revolutionary integrated fluidic circuits (IFCs) enable automated molecular biology that significantly minimizes pipetting steps, hands-on time and reagent consumption while maximizing efficiency, cost savings and robust data production.
Up to 9.216 datapoint in one run.
- Minimize pipetting steps, hands-on time and reagent consumption
- Find the format that covers your project from 12-192 samples combined with 12-192 assays
- Sample.Assays:
- 192.24
- 96.96
- 48.48
- 24.192
- 12.12*6


Integrated Fluidic Circuits (IFCs)

Fluidigm - Juno GT IFCs
Get results from samples with low amount of DNA
If you deal with low amount of DNA input, the Juno GT IFC allows you to make IFC preamp, giving you better and tighter clustering combined with reduced hands-on time and reagents.
- Tight and polide clustering of samples with Low input DNA
- Save sample, reagents, and hands-on time